Configuring BIOS Settings for Serial Console

Table of Contents

Configuring BIOS Settings for Serial Console

 Configuring BIOS Settings for Serial Console

After making the changes described below and rebooting the machine, you will be able interact with the BIOS UI though both the VGA and the serial console.

Use your existing VGA port and PS2 keyboard to make the following changes:

  1. Power on the SecureSphere appliance.
  2. Press F2 to enter BIOS configuration
  3. Set Server Management-> Console Redirection-> Console Redirection to one of the following:
    • [Serial Port A] (DB9)
    • [Serial Port B] (Rj45)
  4. Set Flow Control to [None].
  5. Set Baud Rate to [38.4K].
  6. Set Terminal Type to [VT100+].
  7. Set Legacy OS Redirection to [Enable].
  8. Save & Exit using "F10".

At this stage the Keyboard and VGA are no loner required.

Was this topic helpful?